The LGT Series of self pressurising cryogenic cylinders has been designed to efficiently store product in its liquid state and provide a regulated stream of gas. Each vessel automatically maintains pressure at a pre-set level using the integral pressure building circuit.
Features :-
Technical Data |
LGT-240MP |
LGT-240HP |
LGT-400MP |
LGT-400HP |
Capacity (ltr) |
240 |
240 |
400 |
400 |
Diameter (mm) |
691 |
691 |
770 |
770 |
Height (mm) |
1366 |
1366 |
1646 |
1646 |
Weight Empty (kg) |
180 |
200 |
290 |
320 |
Weight Full LN2 (kg) |
374 |
394 |
613 |
643 |
Max Working Pressure (bar) |
16.2 |
23.5 |
16.2 |
23.5 |
Regulator Set Point (bar) |
8.5 |
20 |
8.5 |
20 |
Gaseous Withdrawal Rate (m3/hr N2) |
10.5 |
10.5 |
10.5 |
10.5 |
Static Evaporation Rate % per day N2 |
1.7 |
1.7 |
1.5 |
1.5 |
Technical Data |
GT-1000MP |
GT-1000HP |
GT-2000MP |
GT-2000HP |
Capacity (ltr) |
950 |
950 |
2000 |
2000 |
Diameter (mm) |
1058 |
1058 |
1310 |
1310 |
Height (mm) |
2000 |
2000 |
2350 |
2350 |
Base Dims (mm) |
1200 x 1200 |
1200 x 1200 |
1400 x 1400 |
1400 x 1400 |
Weight Empty (kg) |
756 |
|
1450 |
|
Weight Full LN2 (kg) |
1523 |
|
3066 |
|
Max Working Pressure (bar) |
16.2 |
23.5 |
16.2 |
23.5 |
Regulator Set Point (bar) |
8.5 |
20 |
8.5 |
20 |
Gaseous Withdrawal Rate (m3/hr N2) |
10.5 |
10.5 |
10.5 |
10.5 |
Static Evaporation Rate % per day N2 |
1.2 |
1.2 |
1.1 |
1.1 |